Glossary entry

French term or phrase:

Swsp

English translation:

SHGC or G value (unshaded)

Added to glossary by Johannes Gleim
Sep 7, 2020 17:51
3 yrs ago
27 viewers *
French term

Swsp

French to English Tech/Engineering Construction / Civil Engineering Thermal efficiency of windows
Swsp: Facteur solaire pour les fenêtres sans protection (le facteur solaire Swsp indique le pourcentage de chaleur solaire collectée par la fenêtre vers l'intérieur du logement).

This concerns the energy efficiency of windows. I have looked it up and I think the abbreviation might be SHGC in English, but could anyone please confirm this?

Thank you
Proposed translations (English)
5 SHGC or G value (unshaded)
References
Swsp
Change log

Sep 12, 2020 15:01: Johannes Gleim Created KOG entry

Discussion

Johannes Gleim Sep 9, 2020:
All indices have a specific meaning for each application. See my annexe.
They do not change the amount of solar radiation, but only serve to distinguish the individual components according to their construction in a comprehensive energy balance calculation.
Jane Golding (asker) Sep 9, 2020:
Thank you all very much for your help, much appreciated!
Kim Metzger Sep 9, 2020:
facteur solaire (Sw) La meilleure efficacité énergétique résulte d’un optimum entre la valeur d’isolation Ug et le facteur solaire « gv » pour le chauffage. Ainsi, le vitrage le plus efficace n’est pas forcément celui qui a la valeur Ug la plus basse si celle-ci est contre balancée par une valeur de facteur solaire très élevée. Par exemple, un double vitrage avec une valeur Ug de 1,1 et un facteur solaire élevé (valeur 0,65) peut être globalement plus efficace qu’un triple vitrage avec un Ug de 0,6 mais un facteur solaire plus faible (valeur 0,56). Ces éléments sont pris en compte dans le calcul du besoin bioclimatique d’un bâtiment « BBIO » qui est un des critères d’évaluation de la conformité d’un ouvrage par rapport à la RT 2012. Le crédit d’impôt pour la transition énergétique (CITE) définit également les critères d’éligibilité d’une fenêtre à partir de ses performances d’isolation thermique (Uw) et de son facteur solaire (Sw). https://befr.saint-gobain-building-glass.com/fr-BE/comment-c...
B D Finch Sep 8, 2020:
@Kim From the question: "Swsp: Facteur solaire pour les fenêtres sans protection" > sp = sans protection, which would be expressed in English as "unshaded". However, I'm pretty sure that "w" doesn't stand for "window". In fact, that acronym is generally used in France, not in England, where we use the term g-value. So, Swsp would be g-value with no shading coefficient. But you'd need to check whether the calculations are equivalent. I believe they are, but am not certain.

https://www.georgebarnsdale.co.uk/find-inspiration/more-info...
"The g-value ... is a measure of how much solar heat is being allowed in through the window. The lower the figure, the less solar heat transferring from outside to in, whereas a higher figure will allow more in.
G-value = total solar heat gain / incident solar radiation"

https://treenergy.fr/definition/
"Le facteur solaire, défini par les coefficients Sw est un nombre sans unité
qui définit la capacité de votre fenêtre à transmettre la
chaleur d’origine solaire à l’intérieur de votre local. Ainsi, plus
le coefficient Sw est élevé, plus votre fenêtre laissera passer l’énergie
solaire.

Kim Metzger Sep 8, 2020:
Sw (S, pour facteur solaire et w, pour la fenêtre Lorsque qu'on vous donne le facteur solaire d'une fenêtre, vérifiez s'il s'agit du facteur solaire des vitrages uniquement, symbolisé g, ou s'il s'agit du facteur solaire de la fenêtre entière, symbolisé Sw (S, pour facteur solaire et w, pour la fenêtre: window en anglais).
Lorsqu'on parle de protection solaire, on utilise alors soit le facteur « gtot », qui est le facteur solaire de l’ensemble « vitrage et protection solaire (ou fermeture) », soit le facteur « Sws », qui est le facteur solaire de la fenêtre et de sa protection solaire (ou fermeture).
https://fenetre.ooreka.fr/astuce/voir/651237/facteur-solaire...
Kim Metzger Sep 8, 2020:
Le facteur solaire Sw permet d’évaluer l’apport d’énergie naturelle qu’une fenêtre est capable de transmettre à l’intérieur de l’habitat. C’est cette valeur que les consommateurs regardent et comparent lors de l’achat d’une nouvelle menuiserie. Plus le coefficient solaire est grand, plus la fenêtre laisse entrer l’énergie du soleil. Une fenêtre dotée d’un bon facteur solaire vous permettra de chauffer vos pièces gratuitement lorsque le soleil l’illuminera. Vous utiliserez moins votre chauffage et réaliserez des économies.
https://www.fenetre123.fr/fenetres-pvc/coefficients/sw/#:~:t...
Kim Metzger Sep 8, 2020:
Sw factor, but couldn't find what "sp" stands for. "The module allows you to calculate Sw solar factor, which is an indicator of the gains of the transferred solar heat by the window construction into the room.
This value relies on several factors. First of all, it depends on thermal insulation parameters of both the whole structure (Uw value) and the glass itself. The greater the amount of solar heat passed, the higher the value of Sw factor is.
The window design with the high Sw factor satisfies the condition of applicability for passive heating buildings. The module is useful primarily for manufacturers of windows who export their products or have their retail outlets throughout the European Union.
https://www.stolcad.com/en/products/modules/sw-factor
B D Finch Sep 8, 2020:
@phil No, it's an abbreviation. I noticed it on a French gov. website in relation to regulations or recommendations for buildings. It might be simply translatable as "G-value for unshaded windows".
philgoddard Sep 8, 2020:
Isn't it a term in an equation rather than an abbreviation?
B D Finch Sep 7, 2020:
@Asker No, I don't think it is SHGC. For "sans protection", use "unshaded".

Proposed translations

22 hrs
Selected

SHGC or G value (unshaded)

I start with the French Wikipedia page added to BDs translation of Sw https://www.proz.com/kudoz/french-to-english/construction-ci...

Le facteur solaire d’une paroi est le rapport entre l’énergie due au rayonnement solaire transmise et l’énergie reçue par la paroi. Cette paroi peut être de toutes sortes, opaque, vitrée etc.
:
Le facteur solaire g ou transmission énergétique
:
Il représente la somme du rayonnement transmis et celle du rayonnement absorbé puis retransmis vers l'intérieur par le vitrage.
:
Aux États-Unis, c'est principalement le Solar Heat Gain Coefficient (SHGC) qui est utilisé, et anciennement le Shading Coefficient (SC).
https://fr.wikipedia.org/wiki/Facteur_solaire

Solar gain through windows includes energy transmitted directly through the glass and energy absorbed by the glass and frame and then re-radiated into the space.
:
G-value (sometimes also called a Solar Factor or Total Solar Energy Transmittance) is the coefficient commonly used in Europe to measure the solar energy transmittance of windows. Despite having minor differences in modeling standards compared to the SHGC, the two values are effectively the same. A g-value of 1.0 represents full transmittance of all solar radiation while 0.0 represents a window with no solar energy transmittance. In practice though, most g-values will range between 0.2 and 0.7, with solar control glazing having a g-value of less than 0.5
Solar Heat Gain Coefficient (SHGC)
SHGC is the successor to the shading coefficient used in the United States and it is the ratio of transmitted solar radiation to incident solar radiation of an entire window assembly. It ranges from 0 to 1 and refers to the solar energy transmittance of a window or door as a whole, factoring in the glass, frame material, sash (if present), divided lite bars (if present) and screens (if present).[2] The transmittance of each component is calculated in a similar manner to the shading coefficient. However, in contrast to the shading coefficient, the total solar gain is calculated on a wavelength-by-wavelength basis
https://en.wikipedia.org/wiki/Solar_gain#G-Value

See also https://fr.wikipedia.org/wiki/Vitre#Le_facteur_solaire_g_ou_...

Calculating the Effect of External Shading on the Solar Heat Gain Coefficient of Windows
:
The Solar Heat Gain Coefficient (SHGC) is a common metric for characterizing the amount of solar gain that enters through a building component. It is most relevant for non-opaque parts of the building envelope such as windows and skylights. It is defined as the ratio of the incident solar radiation and the heat gain through the building component due to this solar gain.
:
We can quantify the effect that the shade is having on the SHGC of the window by calculating the SHGC of the window without shades and the aSHGC with external shades in place
[formule]
Where 𝑄unshaded is the amount of solar energy transmitted through the window due to the incident solar radiation without a shade. 𝐼dir+diff,unshaded is the total amount of solar radiation that is incident on the window without the presence of an external shade. Of note is that the aSHGC value is calculated with the unshaded incident solar radiation. This is the key aspect in calculating the adjusted SHGC (aSHGC) value, which indicates the SHGC of the window with a shade present.
:
Conclusion
The presented method uses two standard tools (EnergyPlus and Berkeley Lab WINDOW) to calculate a seasonal weighted adjusted SHGC which accounts for the effect of external shading. This method can be referenced by building codes to allow them to properly account for the effect of a shade on the SHGC of a window.
https://windows.lbl.gov/sites/default/files/lbnl-2001057.pdf

I conclude from this that the Solar Heat Gain Coefficient of Windows (SHGC) is in fact the term researched and equals to the G value. This is also confirmed by the given definition:

Swsp: Facteur solaire pour les fenêtres sans protection (le facteur solaire Swsp indique le pourcentage de chaleur solaire collectée par la fenêtre vers l'intérieur du logement).
Or in English:
SHGC: Solar factor for unshaded windows (the SHGC solar factor indicates the percentage of solar heat collected by the window towards the inside of the dwelling).
(the SHGC considers the whole window, i.e. panes and frames)

while aSHGC is the shaded equivalent. I see no real difference between « Sw » and « Swsp ». Both are translated by "SHGC or G value" depending on the target country.


--------------------------------------------------
Note added at 1 day 15 hrs (2020-09-09 09:41:32 GMT)
--------------------------------------------------

Very easy to goggle for "Swsp" "Facteur solaire", e.g.

Facteur solaire pour les fenêtres sans protection (le facteur solaire Swsp indique le pourcentage de chaleur solaire collectée par la fenêtre vers l'intérieur du logement).
https://journaldemonaco.gouv.mc/Journaux/2020/Journal-8499/A...
(Arrêté Ministériel n° 2020-539)

1.2 Facteur de transmission solaire S
Le facteur solaire global de la paroi vitrée, déterminé selon ce fascicule, caractérise la capacité de la paroi à transmettre le rayonnement solaire entre les deux milieux qu’elle sépare
:
1.3 Facteur de transmission lumineuse TL
Le facteur de transmission lumineuse de la paroi vitrée, déterminé selon ce fascicule, caractérise la capacité de la paroi à transmettre le rayonnement lumineux entre les deux milieux qu’elle sépare

1.5.2 Symboles et indices
1.5.2.1 Coefficient U

Tableau II: Indices
s Lame d’air ou de gaz, fermeture, store intérieur, extérieur ou entre vitrage
w Fenêtre ou porte fenêtre nue
ws Fenêtre, porte ou porte fenêtre nue avec fermeture ou store
p Panneau opaque


1.5.2.2 Facteur solaire S
Tableau III: Nomenclature pour le facteur solaire

Pour la norme XP P50-777, les indices de caractérisation des composants sont les suivants:
o w: paroi vitrée associée à ses éléments opaques sans protection rapportée en place;
o ws: paroi vitrée associée à ses éléments opaques avec protection rapportée en place.
Dans le cadre du facteur de transmission lumineuse, on retient les notations suivantes:
o sp,b: ramené à la baie, avec prise en compte de l’intégration à l’ouvrage, sans protection rapportée en place;

2.9.3.2Calcul du facteur de transmission solaire Sw

3.2.2 Formules générales
3.2.2.1 Paroi transparente ou translucide sans protection rapportée en place
L’application de la méthode conduit aux résultats suivants:
Tableau XVII: Sorties des facteurs de transmission solaire pour les cas courants de baies sans protection rapportée
Résultat de l’application de la méthode
C | E
Swsp-c,b | Swsp-e,b
http://www.rt-batiment.fr/IMG/pdf/3-fascicule_parois_vitrees...

Sur la base des indices mis en évidence, j'interprète les indices individuels comme suit :
- Fenêtre, porte ou porte fenêtre nue avec fermeture ou store
- avec lame d’air ou de gaz, fermeture, store intérieur, extérieur ou entre vitrage
- et vitrage.

Based on the highlighted indices I can retain my proposal, and apply it to the specific application:
- Bare window, door or French window with closure or sunshade
- with air or gas layer, closure, internal or external blind or between glazing
- and opaque panel.

--------------------------------------------------
Note added at 1 day 16 hrs (2020-09-09 09:57:48 GMT)
--------------------------------------------------

Correction d'un erreur de frappe :

- Fenêtre, porte ou porte fenêtre nue avec fermeture ou store
- avec lame d’air ou de gaz, fermeture, store intérieur, extérieur ou entre vitrage
- et panneau opaque.
Note from asker:
Thank you very much for your help. This seems to be correct,
Peer comment(s):

neutral B D Finch : NB The American SHGC is similar but not identical to the Sw or g-value. I believe that the Sw and g-value both conform to the European standard. Also, Britain, being colder, favours a higher g-value (0.5 to 0.7) than France (0.45)
21 hrs
Similar and identical for practical use. It's ot a matter of belief, but of research. We do not discuss what g value is preferred in different contries, either.
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thank you very much. "

Reference comments

10 mins
Reference:

Swsp

Peer comments on this reference comment:

neutral B D Finch : That is the US version of a solar factor, which isn't exactly the same as the European one. The British G-value is, I believe, based on the European standard. Also, it doesn't answer the question for Swsp.
1 hr
Something went wrong...